Maintenance work on the carrier
7.16 Electrical system
13.02.2018
Maintenance manual 3 302 719 en 7 - 105
GMK6300L-1
Checking the connecting terminals
Keep the batteries clean and dry.
Remove any dirty connecting terminals (1)
and clean them.
Fasten any loose connecting terminals.
Grease the connecting terminals and poles
lightly with a special battery terminal
grease.
Checking the acid level
Batteries without covers (1) are maintenance-
free.
Remove all caps (1).
The acid level must be above the plates.
If the acid level is too low
Top it up using only distilled water until
the plates are covered.
Tightly bolt on all covers (1).
After checking
Shut the cover (2) on the battery box.
Attach the selector handle and switch on the
battery master switch (1).
Check the timers on the tachograph and on
the auxiliary heater;
à Manual de
instrucciones
.
Enter the code for the radio; à Separate
engine operating instructions, provided by the
manufacturer
.