Maintenance work on the superstructure
8.3 Engine
8 - 24 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
Changing
Draining when the engine is cold
Open the cap (1) on the expansion tank.
Place a receptacle under the valve (2) in
the cooling circuit.
Screw the connecting piece and hose on
to the valve (2) and drain the coolant;
à Handling the valves, p. 7 - 92.
Remove the receptacle.
Change the silicate cartridge; à p. 8 - 25.
Topping up when the engine is cold
Slowly top up the expansion tank (1) with
coolant until it is filled up to the lower
edge in the filler neck.
Wait about 1 minute. Add more coolant
if necessary.
Close the cover (1).
Check it when the engine is warm
Start the engine.
Let the engine run at idling speed for approx. 5 minutes.
Switch off the engine.
Check the coolant level when the engine is warm; à Checking the coolant
level
, p. 8 - 15.