Maintenance overview
5.4 Measures required for winch monitoring
5 - 26 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
5.4.3 Example
A GMK6300L-1 is equipped with a separate operating hours counter for the
hoist and is classified by Manitowoc Crane Group Germany GmbH as
follows:
The used proportion S of theoretical service life is calculated based on the
individual inspection intervals as follo
ws:
1. Inspection (1st year)
The truck crane was used for assembly work during the previous year:
Load spectrum L1,
i.e. Km
1
= 0.125.
The operating hours counter for the main hoist reads 160 h, i.e. T1 = 160 h.
The used proportion S
1
of theoretical service life after the first inspection
therefore is:
Remaining theoretical service life:
D1 = 3200 h -160 h = 3040 h.
The above values are entered in the table (see table example p. 5 - 28).
2. inspection (2nd year)
The truck crane was used for unloading work on docks: Load spectrum:
L3, i.e.
Km
2
= 0.5.
The operating hours counter for the main hoist reads 640 h, i.e. during this
period: 640 hrs. - 16
0 hrs. = 480 hrs. (160 hrs. were used during the first year)
T2 = 480 hrs.
Power unit group:
M 3
Load spectrum: light L1, Km = 0.125
Theoretical service life: D = 3200 h
S
i
0,125
0,125
---------------
160 h× 160 h==

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals