Maintenance work on the carrier
7.3 Engine
7 - 20 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
• Have the radiator units (1), (2), (3) and (4) opened up by the repair crew
so that the radiator fins are accessible.
• Have the radiator fins cleaned on both sides, using suitable cleaning
agents.
• Have the fan impeller (6) cleaned.
• Have the cooling air baffle (7) cleaned.
• Have the hoses and connections checked for damage and leaks.
• Have any damaged parts replaced.
After checking/
cleaning
• Remove all tools and cleaning equipment.
• Check that all the grilles (5) and plates (7) are secure.
• Start the engine and wait until the fan impellers are rotating.
• Check that the fan impellers are running freely.
• Check the respective temperature displays in the driver's cab; à Manual
de instrucciones
.
• Switch off the engine.
• Check the radiator and connections for leaks.