07D01.13
GPA20 shiftable shaft
G . Flange shaft
Special points
- The flange shaft (31) makes it possible to inter-
change the end-fitting (32) (6 or 21 splines).
- This end-fitting is integral with the shaft (31) via pins
(33) and screws (34).
- When the power take-off is not in use, the coupling
end is masked (depending on option):
• either by a bayonet cap (29) held in place by special
spacers (27),
• or by a twist cap (30) (Fig. 12).
R
EMARK: To allow for the removal of the end-fitting,
introduce a measuring rod into one of the two holes
drilled into the housing unit (14). Lock by gently turning
the end-fitting. Take out the screws (34).
Tightening torque
Screw (34): 100 - 130 Nm