WINTEST - Issue 5.a
GUF513.3
AUTOTRONIC 5 - PowerShuttle - Error codes
NOTE: Error codes are managed from soft version
01.03.
A . Reading error codes
Reading codes on the instrument panel
Autotronic 5 continuously monitors the power shuttle
function and PTO.
The user is informed of a fault by:
- The flashing reverse indicator light (9) for the Power-
Shuttle function (Fig. 1),
- The flashing PTO indicator light (22) for the PTO func-
tion and PowerShuttle calibration (Fig. 1).
Only one error code can be displayed at a time.
Reading principle:
1. The indicator light flashes in a rapid burst to signal
the code is about to be displayed
2. 1st series of flashes displays the error code
decimal.
3. Approximately one second without flash precedes
display of the error code unit.
4. 2nd series of flashes displays the error code unit.
5. The procedure restarts from the beginning.
0
A B C D
+
-
!
P
E
0000000
5 25
20
15
10
1
1/2
!
RPMx100
9
22
MA-11-01276A
Fig. 1