Massey Ferguson 5400 - Issue 1.a
09K01.6
57 l/min Open Centre tests
Testing the flow divider (if fitted)
- Connect a flowmeter to a quick-disconnect coupling
on auxiliary spool valve no.1 located by flow
divider "D" (Fig. 3).
Connect the return directly to the housing via the
transmission filler port.
- Connect a suitable pressure gauge to the diagnostics
connector (1) (Fig. 1).
I
MPORTANT: Check that the flowmeter load valve is
open fully.
- Activate the spool valve.
- Adjust the flowmeter load valve to obtain P1.
- Check the flow rate of the divider by turning the
adjusting knob shown (Fig. 3).
- Check Q2.
N
OTE: Do not consider the value of the pressure
gauge fitted to the flowmeter. Look at the separate
pressure gauge connected to the diagnostics
connector (1) (Fig. 1).
Checking kick-out pressure on an auxiliary
spool valve fitted with automatic return to
neutral
- Connect a flowmeter to the relevant spool valve
(no.3 for example) (Fig. 4).
- Connect a suitable pressure gauge to the diagnostics
connector (1) (Fig. 1).
- Run the engine at 2200 rpm.
- Activate the spool valve in automatic return position.
Release the lever and gradually shut the flowmeter
load valve until the lever returns to neutral position.
- Check the kick-out pressure:
P1 = 150 - 170 bar.
I
MPORTANT: Make sure that the spool valve is in the
automatic return position and not in the floating posi-
tion.
N
OTE: Do not consider the value of the pressure
gauge fitted to the flowmeter. Look at the separate
pressure gauge connected to connector (1) (Fig. 1).
Engine speed
(rpm)
P1
(bar)
Q2
(l/min)
2200 0 to 150 0 to 53
Fig. 3