EasyManuals Logo

Megmeet M5-N Series User Manual

Default Icon
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
Chapter 8 Drive Parameter Object
112
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
Kt
N·M/A
on model
again
P01.15
10h
Electrical constant
Te
0.01~650.00ms
0.01ms
Depending
on model
Power-on
again
P01.16
11h
Mechanical
constant Tm
0.01~650.00ms
0.01ms
Depending
on model
Power-on
again
P01.17
12h
Brake function
0: Without brake
1: With brake
1
Depending
on model
Immediate
P01.18
13h
Encoder selection
0: Reserved
1: Tamagawa serial
intelligent 23-bit
absolute encoder
2: Line-saving
incremental encoder
(with UVW)
3: Reserved
4: Full line
incremental encoder
5: Sharp Eagle 17bit
absolute encoder
(reserved)
6: Nikon 20bit
absolute encoder
(reserved)
7: Reserved
1
1
Immediate
P01.19
14h
Number of
encoder lines
1~4194304
1
2097152
Immediate
P01.20
15h
Encoder
installation initial
angle tuning
0: Disabled
1: Enabled (motor in
static status)
1
0
Immediate
P01.21
16h
Rotation direction
0: A before B
1: B before A
1
0
Immediate
P01.22
17h
Initial angle for
installing encoder
0.0~359.9°
0.1°
180.0
Immediate
P01.23
18h
Initial angle of
encoder Z pulse
0.0~359.9°
0.1°
180.0
Immediate

Table of Contents