Chapter 8 Drive Parameter Object
135
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
effective position
P09.38
27h
Load moment of
inertia ratio
0.00~120.00
0.01
1.00
Immediate
Index 200Ah(P10): Fault and protection parameters
P10.00
01h
Action upon phase
loss
0: Activate protection
upon input and output
phase loss
1: No protection upon
input phase loss
2: No protection upon
output phase loss
3: No protection upon
input and output
1
0
Immediate
P10.01
02h
Action upon
communication
fault
0: Activate protection
and coast to stop
1: Alarm and keep
running
1
0
Immediate
P10.02
03h
Action upon
temperature
sampling
disconnection
0: Activate protection
and coast to stop
1: Alarm and keep
running
1
0
Immediate
P10.03
04h
Reserved
P10.04
05h
Overtravel stop
mode selection
0: Activate protection
and coast to stop
1: Alarm, decelerate
to zero, keep position
locked
1
2
Immediate
P10.05
06h
Reserved
P10.06
07h
Overload
protection setting
for motor
0: Activate protection
and coast to stop
1: Alarm and keep
running
1
1
Immediate
P10.07
08h
Motor overload
protection gain
20.0%~300.0%
0.1%
100.0
Immediate
P10.08
09h
Runaway
protection
0: Disabled
1: Enabled
1
1
Immediate