Chapter 8 Drive Parameter Object
153
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
Index 2012h(P18): Advanced parameters
P18.00
01h
User password
P18.01
02h
Drive operation
mode
1: VC
2: IF (P02.00 is
invalid at this time,
and the speed
reference is P06.01)
3: VF (same as
above)
1
1
Immediate
P18.02
03h
Current loop gain
1~50.00
0.01
10.00
Immediate
P18.03
04h
Current loop
integral
0.5~100.0ms
0.1ms
10.0
Immediate
P18.04
~P18.15
05h~
10h
Advanced
parameters
P18.16
~P18.28
P11h~
1Dh
Reserved
Index 2014h(P20): Bus configuration group parameters
P20.00
01h
Synchronization
coefficient
0~65535
1
0
Power-on
again
P20.01
02h
Upper limit of
synchronization
coefficient
0~65535
1
-
_
P20.02
03h
Reserved
0~65535
1
-
_
P20.03
04h
Reserved
0~65535
1
-
_
P20.06
07h
Bus output torque
filtering time
0~65535ms
1
0
Immediate
P20.08
09h
Slave station axis
address
0~65535
1
0
Power-on
again
P20.09
0Ah
Master station
configuration
address
0~65535
1
-
_
P20.10
0Bh
Reserved
0~65535
1
0
Power-on
again