Chapter 8 Drive Parameter Object
147
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
Encoder unit
P11.42
2Bh
Rotating load
single-turn position
In absolute position
rotation mode, the
unit of position
command within one
revolution of the
rotation load
Comman
d unit
_
P11.43
2Ch
Mechanical angle
(number of pulses
from origin)
Encoder
unit
_
P11.44
2Dh
Electrical angle
0.00~360.00°
0.01°
_
P11.44
~P11.54
P2Eh~37h
Reserved
Index 200Ch(P12): Servo positioning parameters
P12.00
01h
Homing selection
0: Disabled
1: Homing enabled by
the HomingStart
signal input from DI
2: Electrical homing
enabled by the
HomingStart signal
input from DI
3: Homing enabled
immediately upon
power-on
4: Homing performed
immediately
5: Electrical homing
started
6: Current position as
the home
1
0
Immediate
P12.01
02h
Homing mode
0: Forward, home
switch as
deceleration point
and home
1: Reverse, home
switch as
deceleration point
and home
1
9
Immediate