Chapter 8 Drive Parameter Object
114
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
direction as the
forward direction
(reverse mode, B
before A)
P02.04
05h
Reserved
P02.05
06h
Reserved
P02.06
07h
Reserved
P02.07
08h
Z pulse output
polarity selection
0: Positive output (Z
pulse is high level)
1: Negative output (Z
pulse is low level)
1
0
Immediate
P02.08
09h
Stop mode
0: Decelerate to stop
1: Coast to stop
1
0
Immediate
P02.09
0Ah
Emergency stop
enable
0: No operation, keep
the current running
state
1: Enable emergency
stop, stop according
to the set stop mode
(P02.08), and alarm
AL.038
1
0
Immediate
P02.10
0Bh
Delay from
brake outputting
ON signal to
command
received
20~500ms
1ms
250
Immediate
P02.11
0Ch
Delay from brake
outputting OFF
signal to motor
power-off in the
standstill state
1~1000ms
1ms
150
Immediate
P02.12
0Dh
Brake command
output speed limit
value
0~3000.0rpm
1rpm
10.0
Immediate
P02.13
0Eh
Servo OFF brake
command waiting
time
1~30000ms
1ms
500
Immediate