Chapter 8 Drive Parameter Object
128
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
P07.03
04h
Torque digital
reference value
-400.0%~+400.0%
0.1%
0.0
Immediate
P07.04
05h
Torque reference
acceleration/
deceleration time
0~6553.5ms
0.1ms
0
Immediate
P07.05
06h
Torque command
filter time constant
0~30.0ms
0.1ms
1.0
Immediate
P07.06
07h
Second torque
command filter
time constant
0~30.0ms
0.1ms
1.0
Immediate
P07.07
08h
Speed/torque
switching point
0.0%~400.0% initial
torque
0.1%
100.0
Immediate
P07.08
09h
Speed/torque
switching delay
0~1000.0ms
0.1ms
0.0
Immediate
P07.09
0Ah
FWD speed limit
channel
0: FWD speed limit
value
1: Bus speed limit
value
2: MIN(FWD speed
limit value, bus speed
limit value)
1
1
Immediate
P07.10
0Bh
FWD speed limit
value
0.0%~100.0%
0.1%
100.0
Immediate
P07.11
0Ch
REV speed limit
channel
0: REV speed limit
value
1: Bus speed limit
value
2: MIN(REV speed
limit value, bus speed
limit value)
1
1
Immediate
P07.12
0Dh
REV speed limit
value
0.0%~100.0%
0.1%
100.0
Immediate
P07.13
0Eh
Torque reached
reference value
0.0~400.0%
0.1%
0.0
Immediate
P07.14
0Fh
Torque reached
valid value
0.0~400.0%
0.1%
20.0
Immediate

Table of Contents