EasyManua.ls Logo

MICRO-EPSILON optoCONTROL 2600 - A 6 Standard Measurement Program Data for ODC2600-40

MICRO-EPSILON optoCONTROL 2600
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 80
Appendix | Standard Measurement Program Data for ODC2600-40
optoCONTROL 2600
A 6 Standard Measurement Program Data for ODC2600-40
Standard User
Measurement program data Bright -
dark
Dark -
bright
Width
diameter
Gap Segment
2 - 4
Multi-seg-
ment
USER1
User
-defined
USER2
User
-defined
USER3
User
-defined
USER4
User
-defined
3000 Measurement program data
Name EDGEHL EDGEHL DA GAP SEG_2_4 MULT SEG
Segment 1 1 1 1 1 x
1 Leading edge 1 1
Trailing edge 2 2
2 Leading edge 3
Trailing edge 4
3 Leading edge 5
Trailing edge 6
4 Leading edge 7
Trailing edge 8
Master value +000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
Display offset +000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
Display gain +1000 +1000 +1000 +1000 +1000 +1000
Analog offset +00 000
VDC
+00 000
VDC
+00 000
VDC
+00 000
VDC
+00 000
VDC
+00 000
VDC
Analog gain +1000 +1000 +1000 +1000 +1000 +1000
Higher warning level
(higher WL 1st segm)
+040 0000
mm
+040 0000
mm
+040 0000
mm
+040 0000
mm
+040 0000
mm
+040 0000
mm
Lower warning level
(lower WL 1st segm)
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
Higher tolerance
limit (higher WL 2nd
segment)
+040 0000
mm
+040 0000
mm
+040 0000
mm
+040 0000
mm
+040 0000
mm
+040 0000
mm
Lower tolerance
limit (lower WL 2nd
segment)
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
+000 0000
mm
Median None None None None None None
No of measurements
for average
1 1 1 1 1 1
Measurement mode NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL

Table of Contents