4.4 UTILITY
4.4.1 BASIC SETTINGS
The Basic Configuration section includes the following items:
4.4.1.1 GENERAL
Language: the language can be changed at any moment during the execution of the
program. Select the desired language from the drop-down menu and press <Save>
Unit of Measurement: allows to set the unit of measurement type for viewing test
output values. In particular:
Type
International
US/UK
Height
cm
inch.decimal
Power
W
W
Specific power
W/kg
W/kg
Steps
cm
ft, inch.decimal
Speed
m/s
ft/s
Acceleration
m/s^2
ft/s^2
Weight
kg
lb
Energy
J
J
Specific energy
J/kg
J/kg
Distances
cm
yards, ft, inch.decimal
Step & Stride
cm
ft, inch.decimal
Table 1 - Units of Measurement
4.4.1.2 JUMP TEST CONFIGURATION
The flight and contact time configurations include:
Minimum contact time [ms]: allows you to set a minimum contact time in milliseconds;
if the system registers a contact time shorter than this value, it is considered incorrect
and added to the associated flight time (usually the previous one). This control can be
enabled/disabled by inserting the value 0.
Minimum flight [ms]: allows you to set a minimum flight time in milliseconds; if the
system registers a flight time shorter than this value, it is considered incorrect and
added to the associated contact time. This control can be enabled/disabled by inserting
the value 0.
Maximum flight time [ms]: allows you to set a maximum flight time in milliseconds; if
the flight time is higher, it is considered incorrect. This is, for example, useful for a