4.2.2.7 TAPPING TEST
Main Parameters
Start type: Indicates if the start of the test must take place with a ‘status change’ (i.e.
entering or exiting the bars) or with an ‘external impulse’ coming from the jack sockets
Start: indicates if at the beginning of the test the athlete must be ‘inside the area’ of the
bars or ‘outside the area
Starting foot: if known, the foot with which the test starts (“right” or “left”) can be
indicated, otherwise leave as “not defined
Stop type: Indicates how the end of the test must be interpreted, i.e. as ‘external
impulse’ (e.g. a photocell at the end of the lane) or as ‘timeout’ (the number of
milliseconds of Test timeout can be customized in Utility Basic Configuration)
Finish: for the Stop type = ‘Timeout’ it is necessary to specify if, at the end of the test,
the athlete must be ‘inside the area’ of the bars or ‘outside the area
Test length: appears only if Stop type = ‘End of Time’ and specifies how many
minutes:seconds the test must last (from 00:01 to 09:59)
Secondary Parameters
Minimum contact time [ms]: see above
Minimum flight time [ms]: see above
Maximum flight time [ms]: see above
Minimum gap between feet [cm]: see above
Minimum foot length [cm]: see above
In order to perform a Tapping Test it is important that the athlete’s feet are vertical to the OptoJump
bars
Figure 48 Correct execution of a Tapping Test