When Nozzle Clogging Cannot Be Solved
4-23
1
1
1
4
Routine Maintenance
At the time of the start of printing, check whether or not there is a
nozzle that can not be recovered
Depending on the print conditions that have been set, there are times when it can not be recovered even
register the nozzle recovery.
With this setting, whether recoverable or not can be checked and the operation for non recoverable case can
be selected.
1
Select [NOZZLE RECOVERY] of the maintenance
menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [NOZZLE RECOVERY].
(4) Press the key.
2
Press to select [CHECK BEFORE PRINT]
and press the key.
3
Press to select a set value and press the
key.
Set value:OFF, CONTINUE, STOP
OFF :Does not check at the start of printing.
CONTINUE :Check at the time of the start of printing. If not
recovered, display the right of screen for 3 seconds,
and then start printing.
STOP : Check at the time of the start of printing. If not
recovered, display the print confirmation screen. When
print, press .
4
Press the key several times to end the setting.
NOZ Z L E RECOVERY
: CHECK BEFORE PR I NT
CONF I RM MENU
:ON
1200x1200 32P Hi Bi
UNRECOVERABLE
1200x1200 32P Hi Bi
UNRECOVERABLE [ ENT ]