3 - 30
3 MOTION DEDICATED PLC INSTRUCTION
[Operation]
Outline operation between CPUs at the DP.CHGAS instruction execution by specifying
"Jn" as Axis No. is shown below.
DP.CHGAS instruction
ON
0.88ms
1 scan
Current value change
DP.CHGAS execution
Complete device (D1+0)
Sequence program
Status display device (D1+1)
at the completion
CPU dedicated transmission
(0.88ms cycle)
END END
ON
Current value change processing
ON : Abnormal completion only
TransferTransfer
Response
data set
Request data set
ON
Start accept flag
(System area)
[Setting range]
(1) Setting of axis to execute the current value change
The axis to execute the current value change set as (S1) sets J + Axis No. in a
character sequence " ".
(S1) usable range
Q173DSCPU 1 to 32
Q172DSCPU 1 to 16
The number of axes which can set are only 1 axis.
Set "J" in a capital letter and use the axis No. set in the command generation axis
parameter as the axis No. to start.
Refer to the "Q173DSCPU/Q172DSCPU Motion controller (SV22) Programming
Manual (Advanced Synchronous Control)" for command generation axis
parameter.
(2) Setting of the current value to change
(n2) usable range
-2147483648 to 2147483647