8 - 4
8 MOTION DEVICES
8.2 Coasting Timer (FT)
Motion device Item Specification
Coasting timer (FT)
(Note-1), (Note-2)
Number of points 1 point (FT)
Data size 32-bit/point (-2147483648 to 2147483647)
Latch
No latch. Cleared to zero at power-on or reset, a count
rise is continued from now on.
Usable tasks Normal, event, NMI
Access Read only enabled
Timer specifications
888
µ
s timer
(Current value (FT) is incremented by 1 per 888
µ
s.)
(Note-1): Use SD720 and SD721 for the 444
µ
s coasting timer.
(Note-2): Use SD722 and SD723 for the 222
µ
s coasting timer.
QDS