5 OPERATION CONTROL PROGRAMS
F/FS G
5.15.6 Output data : MVOUT
Ver.!
Format MVOUT(S1), (S2), (S3), (S4) Number of basic steps 8 or more
[Usable data]
Setting
data
Usable Data
Bit device
Word device
(Note-1)
Constant
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
(S1)
(S2)
(Note-2)
(S3)
(Note-3)
(Note-3)
(Note-3)
(Note-3)
(Note-3)
(Note-3)
(S4)
: Usable
(Note-1): The special register (SD) cannot be used.
(Note-2): Specify the start device which stores the character string data. The character string can be specified directly.
(Note-3): Data is the same format as data to be transferred. The character string can be specified directly.
[Setting data]
Setting data Description Data type of result
(S1)
Vision system (camera) No. to transfer data (1 to 8)
(S2)
Spreadsheet cell or tag to transfer data
(S3)
Data to be transferred
(S4)
Timeout time until data is transferred to vision system
(1 to 32767) [ 10ms]
[Functions]
(1) Data specified with (S3) is transferred to spreadsheet cell or tag specified with
(S2) of vision system specified with (S1).
(2) The Motion SFC program execution transits to the next block without waiting for
the process completion. After process completion, the status storage device value
set in the Ethernet communication line setting parameter is 20 (reception enabled).
(Refer to APPENDIX 3.2.)
Ver.!
: Refer to Section 1.3 for the software version that supports this function.

Table of Contents