EasyManua.ls Logo

Mitsubishi Electric Q173DSCPU - Event Task Disable: DI

Mitsubishi Electric Q173DSCPU
556 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 99
5 OPERATION CONTROL PROGRAMS
F/FS G
5.13.2 Event task disable : DI
Format DI Number of basic steps 1
[Usable data]
Setting
data
Usable Data
Bit device
Word device Constant
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
: Usable
[Setting data]
There are no setting data.
[Functions]
(1) The execution of an event task is disabled.
(2) If an external interrupt or PLC interrupt occurs after execution of the DI instruction,
the corresponding event task is executed once at the execution of the EI
instruction. (If two or more external interrupts or PLC interrupts occur during DI,
the corresponding event task is executed only once at the execution of the EI
instruction.)
(3) During DI, a fixed-cycle event task is not executed.
(4) The execution of an NMI task cannot be disabled.
(5) The DI status is established at power-on or reset of the Multiple CPU system.
EI/DI status does not change by the ON/OFF of PLC ready flag (M2000).
[Errors]
(1) An operation error will occur if:
• This instruction is used with other than a normal task.
[Program examples]
(1) Program which disables the execution of an event task.
DI

Table of Contents

Related product manuals