4 - 6
4 MOTION SFC PROGRAMS
Combining the basic type branches/couplings provides the following application types,
which are defined as in the basic types.
Name Motion SFC chart symbol
List
representation
Function
Appli-
cation
type
Selective branch
|
Parallel branch
IFBm
PABm
IFT2IFT1
PAT1 PAT2
CALL Kn
IFBm
IFT1
SFT Gn
PABm
PAT1
CALL Fn
:
JMP PAEm
PAT2
CALL Fn’
:
(JMP PAEm)
PAEm
JMP IFEm
IFT2
SFT Gn’
CALL Fn’’
:
(JMP IFEm)
IFEm
SFT Gn’’
• After a selective branch, a parallel branch can be
performed.
Parallel coupling
|
Selective coupling
PAEm
IFEm
• The selective coupling point can be the same as
the coupling point of a parallel coupling for
selective branch
parallel branch. Note that in
the Motion SFC chart, this type is displayed in
order of a parallel coupling
a selective
coupling, as shown on the left.
• In this case, a pointer (Pn) cannot be set between
the parallel coupling point (PAEm) and the
selective coupling point (IFEm).
Parallel branch
|
Selective branch
IFBm
PABm
PAT1
IFT1 IFT2
PAT2
SFT Gn
PABm
PAT1
CALL Fn
IFBm
IFT1
SFT Gn’
CALL Fn’
:
JMP IFEm
IFT2
SFT Gn’’
CALL Fn’’
:
(JMP IFEm)
IFEm
JMP PAEm
PAT2
CALL Fn’’’
:
CALL Kn
(JMP PAEm)
PAEm
SFT Gn’’’
• After a parallel branch, a selective branch can be
performed.
Selective coupling
|
Parallel coupling
PAEm
IFEm
• The parallel coupling point can be the same as the
coupling point of a selective coupling for parallel
branch
selective branch.
Note that in the Motion SFC chart, this type is
displayed in order of a selective coupling
a
parallel coupling, as shown on the left.
• In this case, a pointer (Pn) cannot be set between
the selective coupling point (IFEm) and the
parallel coupling point (PAEm).