EasyManua.ls Logo

Mitsubishi Electric Q173DSCPU - Page 478

Mitsubishi Electric Q173DSCPU
556 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 - 11
12 ERROR CODE LISTS
Error
code
Details
code
Error factor
Error Processing Corrective Action
Name Description
16320
Operation (/)
execution error
The divisor is 0.
The block processing
on executing is
stopped and the next
block is executed.
Correct the program so that the divisor is
other than 0.
16321
Remainder (%)
execution error
16322
Device set (SET)
execution error
• The device No. which indirectly specifies
(D) is illegal.
• (D) is a device which is write-disabled.
• Correct the program so that the device No.
which indirectly specifies (D) is proper.
• Correct the program to set a write-enabled
device at (D).
16333
Device reset (RST)
execution error
16334
Device set (SET=)
execution error
16335
Device reset (RST=)
execution error
16336
Device output (DOUT)
execution error
16337
Device input (DIN)
execution error
The device No. which indirectly specifies (D)
is illegal.
Correct the program so that the device No.
which indirectly specifies (D) is proper.
16338
Bit device output
(OUT=) execution
error
16368
Direct specification 16
bit Multiple CPU area
device for CPU No.1
(U3E0\G10000 to)
read error
Multiple CPU area device number is outside
the range that set by the parameter.
Correct the program so that Multiple CPU
area device number is within the range set
in the parameter.
16369
Direct specification 32
bit Multiple CPU area
device for CPU No.1
(U3E0\G10000 to)
read error
16370
Direct specification 64
bit Multiple CPU area
device for CPU No.1
(U3E0\G10000 to)
read error
16371
Direct specification 16
bit Multiple CPU area
device for CPU No.2
(U3E1\G10000 to)
read error
16372
Direct specification 32
bit Multiple CPU area
device for CPU No.2
(U3E1\G10000 to)
read error
16373
Direct specification 64
bit Multiple CPU area
device for CPU No.2
(U3E1\G10000 to)
read error
16374
Direct specification 16
bit Multiple CPU area
device for CPU No.3
(U3E2\G10000 to)
read error
16375
Direct specification 32
bit Multiple CPU area
device for CPU No.3
(U3E2\G10000 to)
read error

Table of Contents