12 - 13
12 ERROR CODE LISTS
Error
code
Details
code
Error factor
Error Processing Corrective Action
Name Description
16412
16-bit integer type
scaling (SCL)
execution error
• (S1) is outside the range of 0 to 3.
• The device number of (S3) is odd-
numbered.
• (S3) to (S3) + (2N + 1) is outside the
device range.
• The number of points is outside the range
of 2 to 4000.
• In the sequential search ((S1) is 0 or 1),
the points corresponding to the input
values (for positive conversion: X
0 to XN-
1
/for inverse conversion: Y0 to YN-1) are
not in ascending order.
• The conversion results are outside the
range of the data type (D).
The block processing
on executing is
stopped and the next
block is executed.
• Correct the program so that the (S1) is
within the range of 0 to 3.
• Correct the program so that the (S3) is
even-numbered device.
• Correct the program so that the devices
from (S3) to (S3) + (2N + 1) are within the
range.
• Correct the program so that the number of
points is within the range of 2 to 4000.
• Correct the program so that the points
corresponding to the input values (for
positive conversion: X
0 to XN-1/for inverse
conversion: Y
0 to YN-1) increases
monotonically.
• Correct the program so that the conversion
results are within the data type (D).
16413
32-bit integer type
scaling (DSCL)
execution error
• (S1) is outside the range of 0 to 3.
• The device numbers of (S2), (S3), and (D)
are odd-numbered.
• (S3) to (S3) + (4N + 1) is outside the
device range.
• The number of points is outside the range
of 2 to 2000.
• In the sequential search ((S1) is 0 or 1),
the points corresponding to the input
values (for positive conversion: X
0 to XN-
1/for inverse conversion: Y0 to YN-1) are
not in ascending order.
• The conversion results are outside the
range of the data type (D).
• Correct the program so that the (S1) is
within the range of 0 to 3.
• Correct the program so that the (S2), (S3),
and (D) are even-numbered devices.
• Correct the program so that the devices
from (S3) to (S3) + (4N + 1) are within the
range.
• Correct the program so that the number of
points is within the range of 2 to 2000.
• Correct the program so that the points
corresponding to the input values (for
positive conversion: X
0 to XN-1/for inverse
conversion: Y
0 to YN-1) increases
monotonically.
• Correct the program so that the conversion
results are within the data type (D).
16414
1
Cam data read
(CAMRD) execution
error
Cam No. specified by (S1) is outside the
range of 1 to 256.
Correct the program so that the cam No. is
within the range of 1 to 256.
2
Cam data which No. is specified by (S1)
does not exist in cam open area.
Correct the program to specify a cam No. in
which cam data exists.
3
• In the stroke ratio data format cam, the
cam data first position specified by (S2) is
outside the range of 1 to cam resolution.
• In the coordinate data format cam, the
cam data first position specified by (S2) is
outside the range of 0 to (coordinate
number - 1).
• In the stroke ratio data format cam, correct
the program so that it is within the range of
1 to cam resolution.
• In the coordinate data format cam, correct
the program so that it is within the range of
0 to (coordinate number - 1).
4
• In the stroke ratio data format cam, cam
data operation points is outside the range
of 1 to 4096.
• In the coordinate data format cam, cam
data operation points is outside the range
of 1 to 2048.
• In the stroke ratio data format cam, correct
the program so that it is within the range of
1 to 4096.
• In the coordinate data format cam, correct
the program so that it is within the range of
1 to 2048.
5
The end device number which stores the
cam data is outside the range.
Correct the operation points so that the end
device number which stores the cam data is
within the range.
6
The first number of the storage device for
(D) cam data is not even-numbered.
Correct the program so that the device
number is an even-numbered.
7
Read the cam data with "Read/write
protection" password set.
Execute the cam data read operation after
the password is disabled.