APP - 30
APPENDICES
(3) System setting data of the Motion CPU
System setting is shown below.
(a) Module setting
1) Motion module setting
Manual pulse generator interface module (Q173DPX : Slot 3)
Axis No. Description
P1 Manual pulse generator, Synchronous encoder (INC)
P2 Manual pulse generator, Synchronous encoder (INC)
I/O response time 0.4[ms]
2) PLC module setting
Module
type
Points
Occupied
I/O No.
Base Slot No.
I/O response
time
Input 16 000-00F Main Base 1 10[ms]
Output 16 010-01F Main Base 2