EasyManua.ls Logo

Mitsubishi Electric RD77MS2 - Page 115

Mitsubishi Electric RD77MS2
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
113
3
Operation chart
The following chart shows the operation timing for speed-position switching control (INC mode).
The "in speed control flag" ([Md.31] Status: b0) is turned ON during speed control of speed-position switching control (INC
mode).
RD77MS4 operation example
When using the external command signal [DI] as speed-position switching signal
Operation example
The following operation assumes that the speed-position switching signal is input at the position of the current feed value of
90.00000 [degree] during execution of "[Da.2] Control method" "Forward run: speed/position" at "[Pr.1] Unit setting" of "2:
degree" and "[Pr.21] Current feed value during speed control" setting of "1: Update current feed value".
(The value set in "[Da.6] Positioning address/movement amount" is 270.00000 [degree])
t
V
Positioning start signal
[Y10, Y11, Y12, Y13]
OFF
ON
[Da.8] Command speed
BUSY signal
[X10, X11, X12, X13]
OFF
ON
Positioning complete signal
([Md.31] Status: b15)
OFF
ON
Speed-position switching signal
(External command signal [DI])
OFF
ON
Speed
control
Position
control
Dwell time
OFF
ON
OFF
ON
Movement amount set in
"[Da.6] Positioning address/movement amount"
[Cd.45] Speed-position switching
device selection
[Cd.24] Speed-position
switching enable flag
In speed control flag
([Md.31] Status: b0)
0
Setting details are taken in at positioning start.
0.00000°
90.00000°
Speed-position
switching signal ON
0.00000°
90.00000°
90.00000 + 270.00000
= 360.00000
= Stop at 0.00000 [degree]

Table of Contents