468
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
12.7 Monitor Data
The setting items of the monitor data are explained in this section.
System monitor data
Unless noted in particular, the monitor value is saved as binary data.
Item Default value
Start history (Up to 64 records can be stored) [Md.3] Start information 0000H
[Md.4] Start No. 0000H
[Md.54] Start (Year: month) 0000H
[Md.5] Start (Day: hour) 0000H
[Md.6] Start (Minute: second) 0000H
[Md.60] Start (ms) 0000H
[Md.7] Error judgment 0000H
[Md.8] Start history pointer 0000H
[Md.19] Number of write accesses to flash ROM 0
[Md.50] Forced stop input 0
[Md.51] Amplifier-less operation mode status 0
[Md.52] Communication between amplifiers axes searching flag 0
[Md.53] SSCNET control status 0
[Md.59] Module information RD77MS2: 4000H
RD77MS4: 4001H
RD77MS8: 4002H
RD77MS16: 4003H
[Md.130] F/W version Factory-set product information
[Md.131] Digital oscilloscope running flag 0
[Md.132] Operation cycle setting 0
[Md.133] Operation cycle over flag 0
[Md.134] Operation time 0
[Md.135] Maximum operation time 0