148
4 HIGH-LEVEL POSITIONING CONTROL
4.3 Setting the Block Start Data
Block start
In a "block start (normal start)", the positioning data groups of a block are continuously executed in a set PLC starting from the
positioning data set in "[Da.12] Start data No." by one start.
The control examples are shown when the "block start data" and "positioning data" are set as shown in the setting examples.
Setting examples
Block start data setting example
Positioning data setting example
*1 "1 block" is defined as all the data continuing from the positioning data in which "continuous positioning control" or "continuous path
control" is set in the "[Da.1] Operation pattern" to the positioning data in which "independent positioning control (Positioning complete)"
is set.
Axis 1 block start data [Da.11] Shape [Da.12] Start data No. [Da.13] Special start
instruction
[Da.14] Parameter
1st point 1: Continue 1 0: Block start
2nd point 1: Continue 2 0: Block start
3rd point 1: Continue 5 0: Block start
4th point 1: Continue 10 0: Block start
5th point 0: End 15 0: Block start
Axis 1 positioning data
No.
[Da.1] Operation pattern
1 00: Positioning complete
2 11: Continuous path control 1 block
*1
3 01: Continuous positioning
control
4 00: Positioning complete
5 11: Continuous path control 1 block
6 00: Positioning complete
10 00: Positioning complete
15 00: Positioning complete