12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
Common parameters
Item Setting value, setting range Default value Buffer memory
address
Value set with the engineering tool Value set with a program
[Pr.24] Manual pulse
generator/Incremental
synchronous encoder input
selection
0: A-phase/B-phase multiplied by 4 0 0 33
1: A-phase/B-phase multiplied by 2 1
2: A-phase/B-phase multiplied by 1 2
3: PULSE/SIGN 3
[Pr.82] Forced stop valid/
invalid selection
0: Valid 0 0 35
1: Invalid 1
[Pr.89] Manual pulse
generator/Incremental
synchronous encoder input
type selection
0: Differential output type 0 1 67
1: Voltage output/open collector type 1
[Pr.96] Operation cycle
setting
0000H: 0.888 ms 0000H FFFFH 105
0001H: 1.777 ms 0001H
0002H: 3.555 ms 0002H
0200H: 0.444 ms 0200H
FFFFH: Automatic setting FFFFH
[Pr.97] SSCNET setting 0: SSCNET 01106
1: SSCNET/H 1
[Pr.150] Input terminal logic
selection
b0: SIN1 0: ON at leading
edge
1: ON at trailing
edge
0
1
0 58000, 58001
to
b19: SIN20
[Pr.151] Manual pulse
generator/Incremental
synchronous encoder input
logic selection
0: Negative logic 0 0 58002
1: Positive logic 1
[Pr.152] Maximum number of
control axes
0: No setting 0 0 58003
1 to 16: Maximum number of control axes 1 to 16
[Pr.153] External input signal
digital filter setting
0H: 3.2 ms 0H 6666H 58004
58005
58006
58007
58008
1H: 2.4 ms 1H
2H: 1.6 ms 2H
3H: 1.2 ms 3H
4H: 0.8 ms 4H
5H: 0.4 ms 5H
6H: 0.2 ms 6H