8 CONTROL SUB FUNCTIONS
8.5 Functions to Change the Control Details
263
8
Target position change function
The "target position change function" is a function to change a target position to a newly designated target position at any
timing during the position control (1-axis linear control). A command speed can also be changed simultaneously.
The target position and command speed changed are set directly in the buffer memory, and the target position change is
executed by "[Cd.29] Target position change request flag".
Details of control
The following charts show the details of control of the target position change function.
When the address after change is positioned away from the start point more than the
positioning address:
When the speed is changed simultaneously with changing the address:
When the direction of the operation is changed:
Positioning address Address after change
t
V
Target position change request
Positioning address
Address after change
Target position change request
t
V
Speed before
change
Speed after change
Positioning address
t
V
Address
after
change
Target position change request

Table of Contents