EasyManua.ls Logo

Mitsubishi Electric RD77MS2 - Page 469

Mitsubishi Electric RD77MS2
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 DATA USED FOR POSITIONING CONTROL
12.6 Condition Data
467
12
[Da.19] Parameter 2
Set the parameters as required for the "[Da.16] Condition operator" and "[Da.23] Number of simultaneously starting axes".
[Da.23] Number of simultaneously starting axes
Set the number of simultaneously starting axes to execute the simultaneous start.
[Da.24] Simultaneously starting axis No.1 to [Da.26] Simultaneously starting axis No.3
Set the simultaneously starting axis to execute the 2 to 4-axis simultaneous start.
Set the axis set as simultaneously starting axis.
*1 Do not specify the own axis number or the value outside the range. Otherwise, the error "Condition data error" (error code: 1A00H to
1A05H) will occur during the program execution.
*2 When the same axis number or axis number of own axis is set to multiple simultaneously starting axis number, the error "Condition data
error" (error code: 1A00H to 1A05H) will occur during the program execution.
*3 Do not specify the simultaneously starting axis No.2 and simultaneously starting axis No.3 for 2-axis simultaneously start, and not
specify the simultaneously starting axis No.3 for 3-axis simultaneously start. The setting value is ignored.
[Da.16] Condition
operator
[Da.23] Number of
simultaneously
starting axes
Setting value Setting details
01H: ** = P1 Not used. (No need to be set.)
02H: ** P1
03H: ** P1
04H: ** P1
05H: P1 ** P2 Value The value of P2 should be equal to or greater than the value of P1. (P1 P2)
If P1 is greater than P2 (P1 > P2), the error "Condition data error" (error code:
1A00H to 1A05H) will occur.
06H: ** P1, P2 **
07H: DEV = ON Not used. (No need to be set.)
08H: DEV = OFF
2 to 3
4Value
(positioning data No.)
Set the positioning data No. for starting axis set in "[Da.26] Simultaneously
starting axis No.3"
Low-order 16-bit: Simultaneously starting axis No.3 positioning data No. 1 to
600 (01H to 258H)
High-order 16-bit: Not used (Set "0")
Number of axes Details
2 Simultaneous start by 2 axes of the starting axis and axis set in "[Da.24] Simultaneously starting axis No.1".
3 Simultaneous start by 3 axes of the starting axis and axis set in "[Da.24] Simultaneously starting axis No.1" and "[Da.25] Simultaneously
starting axis No.2".
4 Simultaneous start by 4 axes of the starting axis and axis set in "[Da.24] Simultaneously starting axis No.1" to "[Da.26] Simultaneously
starting axis No.3".
Simultaneously
starting axis
Details
2-axis interpolation Set the target axis number in "[Da.24] Simultaneously starting axis No.1".
3-axis interpolation Set the target axis number in "[Da.24] Simultaneously starting axis No.1" and "[Da.25] Simultaneously starting axis No.2".
4-axis interpolation Set the target axis number in "[Da.24] Simultaneously starting axis No.1" to "[Da.26] Simultaneously starting axis No.3".
0: Axis 1 8: Axis 9
1: Axis 2 9: Axis 10
2: Axis 3 A: Axis 11
3: Axis 4 B: Axis 12
4: Axis 5 C: Axis 13
5: Axis 6 D: Axis 14
6: Axis 7 E: Axis 15
7: Axis 8 F: Axis 16