218
8 CONTROL SUB FUNCTIONS
8.2 Sub Functions Specifically for Machine Home Position Return
Home position return retry operation when the workpiece is outside the range between the
upper and lower limits.
When the direction from the workpiece to the home position is the same as the "[Pr.44] Home position return direction", a
normal machine home position return is carried out. The example shown below is for when "0: Positive direction" is set in
"[Pr.44] Home position return direction".
When the direction from the workpiece to the home position is the opposite direction from the "[Pr.44] Home position return
direction", the operation carries out a deceleration stop when the near-point dog turns OFF, and then carries out a machine
home position return in the direction set in "[Pr.44] Home position return direction". The example shown below is for when
"0: Positive direction" is set in "[Pr.44] Home position return direction".
When the "0: Positive direction" is selected in "[Pr.44] Home position return direction", the upper limit switch
is set to the limit switch in the home position return direction.
When the "1: Negative direction" is selected in "[Pr.44] Home position return direction", the lower limit switch
is set to the limit switch in the home position return direction.
If inverting the install positions of upper/lower limit switches, hardware stroke limit function cannot be
operated properly. If any problem is found for home position return operation, review "Rotation direction
selection/travel direction selection (PA14)" and the wiring for the upper/lower limit switch.
[Pr.44] Home position return direction
Near-point dog
Hardware lower limit switch
Hardware upper limit switch
Zero signal
Movement range
Machine home position return start
Home position
Near-point dog
Hardware lower limit switch Hardware upper limit switch
Zero signal
Movement range
Machine home position return start
Home position
[Pr.44] Home position
return direction

Table of Contents