220
8  CONTROL SUB FUNCTIONS
8.2  Sub Functions Specifically for Machine Home Position Return
Setting method
To use the "home position return retry function", set the required details in the parameters shown in the following table, and 
write them to the Simple Motion module.
When the parameters are set, the home position return retry function will be added to the machine home position return 
control. The set details are validated at the rising edge (OFF  ON) of the PLC READY signal [Y0]. Set "[Pr.57] Dwell time 
during home position return retry" according to the user's requirements.
Refer to the following for the setting details.
Page 407 Basic Setting
 • Parameters are set for each axis.
 • It is recommended that the parameters be set whenever possible with the engineering tool. Execution by a 
program uses many programs and devices. The execution becomes complicated, and the scan times will 
increase.
Setting item Setting 
value
Setting details Factory-set initial 
value
[Pr.48] Home position return retry 1 Set "1: Carry out home position return retry by limit switch". 0
[Pr.57] Dwell time during home position 
return retry
 Set the deceleration stop time during home position return retry. 
(Random value between 0 and 65535 (ms))
0