320
9  COMMON FUNCTIONS
9.6  Amplifier-less Operation Function
Restrictions
 • The following monitor data cannot be used during amplifier-less operation mode.
n: Axis No. - 1
 • The operation of following function differs from the normal operation mode during amplifier-less operation mode.
Storage item Storage details Buffer memory address
[Md.102] Deviation counter value Always "0" during amplifier-less operation mode. 2452+100n
2453+100n
[Md.105] Connected device As the following connected devices artificially during amplifier-less 
operation mode.
• When "1: SSCNET/H" is set in "[Pr.97] SSCNET setting"
00001000H: MR-J4-_B
• When "0: SSCNET" is set in "[Pr.97] SSCNET setting"
00000100H: MR-J3-_B
58660
58661
[Md.106] Servo amplifier software No. Always "0" during amplifier-less operation mode. 2464+100n
2469+100n
[Md.107] Parameter error No. Always "0" during amplifier-less operation mode. 2470+100n
[Md.108] Servo status1 As follows during amplifier-less operation mode.
• READY ON(b0), Servo ON(b1): Changed depending on the all 
axis servo ON signal[Y1] and "[Cd.100] Servo OFF command".
• Control mode (b2, b3): Indicates control mode.
• Servo alarm(b7): Always OFF
• In-position(b12): Always ON
• Torque limit(b13): Changed depending on "[Md.104] Motor 
current value". (Refer to the 2nd and 3rd bullets of restrictions for 
details.)
• Absolute position lost(b14): Always OFF
• Servo warning(b15): Always OFF
2477+100n
[Md.109] Regenerative load ratio/Optional data 
monitor output 1
Always "0" during amplifier-less operation mode. 2478+100n
[Md.110] Effective load torque/Optional data 
monitor output 2
Always "0" during amplifier-less operation mode. 2479+100n
[Md.111] Peak torque ratio/Optional data monitor 
output 3
Always "0" during amplifier-less operation mode. 2480+100n
[Md.112] Optional data monitor output 4 Always "0" during amplifier-less operation mode. 2481+100n
[Md.119] Servo status2 As follows during amplifier-less operation mode.
• Zero point pass (b0): Always ON
• Zero speed (b3): Changed depending on the command speed
• Speed limit (b4): Always ON when the value other than "0" is set 
to the command torque at torque control mode. Otherwise, 
always OFF.
• PID control (b8): Always OFF
2476+100n
Function Operation
External signal selection function When "1: Servo amplifier" is set in "[Pr.116] FLS signal selection", "[Pr.117] RLS signal selection", and "[Pr.118] DOG 
signal selection", the status of external signal at the amplifier-less operation mode start is shown below. 
• Upper/lower limit signal (FLS, RLS): ON
• Near-point dog signal (DOG): OFF
Change "[Md.30] External input signal" to change the signal status. (Refer to the 3rd bullet of restrictions for details.)
When "2: Buffer memory" is set in "[Pr.116] FLS signal selection", "[Pr.117] RLS signal selection", and "[Pr.118] DOG 
signal selection", the upper/lower limit signal (FLS, RLS) and near-point dog signal (DOG) follow the buffer memory 
status of Simple Motion module during amplifier-less operation mode.
Torque limit function Turns ON/OFF torque limit ("[Md.108] Servo status1": b13) depending on "[Md.104] Motor current value". (Refer to the 
3rd bullet of restrictions for details.)