9 COMMON FUNCTIONS
9.7 Virtual Servo Amplifier Function
Restrictions
The following monitor data of virtual servo amplifier differ from the actual servo amplifier.
n: Axis No. - 1
The operation for external signal selection function of virtual servo amplifier differs from the actual servo amplifier.
The following monitor data of virtual servo amplifier differ from the actual servo amplifiers. The writing operation is possible
in the virtual servo amplifier.
n: Axis No. - 1
Storage item Storage details Buffer memory address
[Md.102] Deviation counter value Always "0". 2452+100n
2453+100n
[Md.105] Connected device As the following connected devices artificially.
When "1: SSCNET/H" is set in "[Pr.97] SSCNET setting"
00001000H: MR-J4-_B
When "0: SSCNET" is set in "[Pr.97] SSCNET setting"
00000100H: MR-J3-_B
58660
58661
[Md.106] Servo amplifier software No. Always "0". 2464+100n
to
2469+100n
[Md.107] Parameter error No. Always "0". 2470+100n
[Md.108] Servo status1 READY ON (b0), Servo ON (b1): Changed depending on the all
axis servo ON signal [Y1] and "[Cd.100] Servo OFF command"
Control mode (b2, b3): Indicates control mode.
Servo alarm (b7): Always OFF
In-position (b12): Always ON
Torque limit (b13): Changed depending on "[Md.104] Motor
current value". (Refer to the 2nd and 3rd bullets of restrictions for
details.)
Absolute position lost (b14): Always OFF
Servo warning (b15): Always OFF
2477+100n
[Md.109] Regenerative load ratio/Optional data
monitor output 1
Always "0". 2478+100n
[Md.110] Effective load torque/Optional data
monitor output 2
Always "0". 2479+100n
[Md.111] Peak torque ratio/Optional data monitor
output 3
Always "0". 2480+100n
[Md.112] Optional data monitor output 4 Always "0". 2481+100n
[Md.119] Servo status2 Zero point pass (b0): Always ON
Zero speed (b3): Changed depending on the command speed
Speed limit (b4): Always ON when the value other than "0" is set
to the command torque at torque control mode. Otherwise,
always OFF.
PID control (b8): Always OFF
2476+100n
Function Operation
External signal selection function When "1: Servo amplifier" is set in "[Pr.116] FLS signal selection", "[Pr.117] RLS signal selection", and "[Pr.118] DOG
signal selection", the external signal status immediately after the power supply ON is shown below.
Upper/lower limit signal (FLS, RLS): ON
Near-point dog signal (DOG): OFF
Change the signal status in "[Md.30] External input signal". (Refer to the 3rd bullet of restrictions for details.)
Torque limit function Turns ON/OFF torque limit ("[Md.108] Servo status1": b13) depending on "[Md.104] Motor current value". (Refer to the
3rd bullet of restrictions for details.)
Storage item Storage details Buffer memory address
[Md.30] External input signal When "1: Servo amplifier" is set in "[Pr.116] FLS signal selection", "[Pr.117] RLS signal
selection", and "[Pr.118] DOG signal selection", the external input signal status can be
operated by turning ON/OFF the following signals.
b0: Lower limit signal
b1: Upper limit signal
b6: Near-point dog signal
2416+100n
[Md.104] Motor current value "0" is set after immediately power supply ON.
The motor current value can be emulated by changing this monitor data in user side.
2456+100n