12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
383
12
Monitoring the speed
Monitoring the status of servo amplifier
Monitor details Corresponding item
Monitor the
current
speed
During independent axis control Indicates the speed of
each axis
[Md.22] Feedrate
During
interpolation
control
When "0: Composite speed" is set for "[Pr.20]
Interpolation speed designation method"
Indicates the
composite speed
When "1: Reference axis speed" is set for "[Pr.20]
Interpolation speed designation method"
Indicates the
reference axis speed
Monitor "[Da.8] Command speed" currently being executed. [Md.27] Current speed
Constantly indicates the speed of each axis [Md.28] Axis feedrate
Monitor the current target speed [Md.33] Target speed
Monitor the command speed at speed control mode or continuous operation to torque control mode in the
speed-torque control
[Md.122] Speed during command
Monitor details Corresponding item
Monitor the real current value "feed current value - (command pulse - feedback pulse)". [Md.101] Real current value
Monitor the pulse droop. [Md.102] Deviation counter value
Monitor the motor speed of servo motor. [Md.103] Motor rotation speed
Monitor the current value of servo motor. [Md.104] Motor current value
Monitor the servo amplifier type of each axis. [Md.105] Connected device
Monitor the software No. of servo amplifier. [Md.106] Servo amplifier software No.
Monitor the parameter No. that an error occurred. [Md.107] Parameter error No.
Monitor the status (servo status) of servo amplifier. [Md.108] Servo status1
[Md.119] Servo status2
[Md.125] Servo status3
[Md.500] Servo status7
Monitor the percentage of regenerative power to permissible regenerative value.
Monitor the content of "[Pr.91] Optional data monitor: Data type setting 1" at optional data monitor data type
setting.
[Md.109] Regenerative load ratio/Optional
data monitor output 1
Monitor the continuous effective load torque.
Monitor the content of "[Pr.92] Optional data monitor: Data type setting 2" at optional data monitor data type
setting.
[Md.110] Effective load torque/Optional data
monitor output 2
Monitor the maximum generated torque.
Monitor the content of "[Pr.93] Optional data monitor: Data type setting 3" at optional data monitor data type
setting.
[Md.111] Peak torque ratio/Optional data
monitor output 3
Monitor the content of "[Pr.94] Optional data monitor: Data type setting 4" at optional data monitor data type
setting.
[Md.112] Optional data monitor output 4
Monitor the status of semi closed loop control/fully closed loop control. [Md.113] Semi/Fully closed loop status
Monitor the alarm of servo amplifier. [Md.114] Servo alarm
Monitor the option information of encoder. [Md.116] Encoder option information
Monitor the driver operation alarm number. [Md.502] Driver operation alarm number