14 TROUBLESHOOTING
14.5 List of Error Codes
599
14
1A00H Condition data error The condition setting values are not set or outside the
setting range.
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A01H Condition data error The condition operator setting values are not set or
outside the setting range.
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A02H Condition data error The condition operator is a bit operator, and the
parameter 1 is 32 or more.
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A03H Condition data error An unusable condition operator is set for the set
condition.
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A04H Condition data error The conditional operator has been [parameter 1 is
greater than parameter 2] with 05H (P1 ** P2).
The conditional operator has been [parameter 1 is
greater than parameter 2] with 06H (** P1, P2 **).
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A05H Condition data error The setting value of "address" is outside the setting
range when the condition target is set to "Buffer
memory (1-word/2-word)". (1-word: 0 to 98303, 2-word:
0 to 98302)
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A0CH Condition data error The same axis number is set in "[Da.24] Simultaneously
starting axis No.1", [Da.25] Simultaneously starting axis
No.2" and [Da.26] Simultaneously starting axis No.3".
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A0DH Condition data error The axis number is set in "[Da.24] Simultaneously
starting axis No.1", [Da.25] Simultaneously starting axis
No.2" and [Da.26] Simultaneously starting axis No.3",
that is larger than the common parameter "[Pr.152]
Maximum number of control axes".
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A0EH Condition data error The self axis is set in "[Da.24] Simultaneously starting
axis No.1", [Da.25] Simultaneously starting axis No.2"
and [Da.26] Simultaneously starting axis No.3".
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A0FH Condition data error The "[Da.23] Number of simultaneously starting axes" is
outside the setting range, or the "[Da.23] Number of
simultaneously starting axes" is larger than the "[Pr.152]
Maximum number of control axes".
[Operation status at error occurrence]
The operation is terminated.
Normalize the block start data.
1A10H Illegal data No. The designation of a JUMP destination is executed
currently.
[Operation status at error occurrence]
The positioning data is not executed.
Normalize the positioning data.
1A11H Illegal data No. The positioning data No. tried to be executed is
outside the ranges of 1 to 600, 7000 to 7004, and
9001 to 9004.
The designation of a JUMP destination is outside the
ranges of 1 to 600.
[Operation status at error occurrence]
The positioning data is not executed.
Normalize the positioning data.
Error code
(Hexadecimal)
Error name Error details and causes Remedy