14 TROUBLESHOOTING
14.5 List of Error Codes
617
14
1BF5H Outside auxiliary
shaft clutch
reference address
setting range
Setting value of the synchronous parameter "[Pr.423]
Auxiliary shaft clutch reference address setting" is
outside the setting range.
[Operation status at error occurrence]
Synchronous control does not start.
Set within the range.
1BF6H Outside auxiliary
shaft clutch
smoothing method
range
Setting value of the synchronous parameter "[Pr.428]
Auxiliary shaft clutch smoothing method" is outside the
setting range.
[Operation status at error occurrence]
Synchronous control does not start.
Set within the range.
1BF7H Outside auxiliary
shaft clutch
smoothing time
constant range
Setting value of the synchronous parameter "[Pr.429]
Auxiliary shaft clutch smoothing time constant" is
outside the setting range.
[Operation status at error occurrence]
Synchronous control does not start.
Set within the range.
1BF8H Composite auxiliary
shaft gear operation
overflow
The composite value is overflowed (sign reverse)
because the input values of main shaft and auxiliary
shaft are large.
[Operation status at error occurrence]
Synchronous control is immediately stopped.
Lower the input values of main shaft and auxiliary
shaft.
1C00H Outside speed
change gear range
Setting value of the synchronous parameter "[Pr.434]
Speed change gear" is outside the setting range.
[Operation status at error occurrence]
Synchronous control does not start.
Set within the range.
1C01H Outside speed
change ratio:
denominator range
The synchronous parameter "[Pr.437] Speed change
ratio: Denominator" is set to 0 or lower.
[Operation status at error occurrence]
Synchronous control does not start.
Set a value within the range of 1 to 2147483647.
1C02H Outside speed
change gear
smoothing time
constant range
The synchronous parameter "[Pr.435] Speed change
gear smoothing time constant" is set other than 0 to
5000.
[Operation status at error occurrence]
Synchronous control does not start.
Set a value within the range of 0 to 5000.
1C03H Speed change gear
overflow
Overflow (sign reversion) occurred in input values,
because the speed change ratio of speed change gear
is too large.
[Operation status at error occurrence]
Synchronous control is immediately stopped.
Set a smaller absolute value for the synchronous
parameter "[Pr.436] Speed change ratio:
Numerator".
Set a larger value for the synchronous parameter
"[Pr.437] Speed change ratio: Denominator".
Decrease the input axis speed.
1C10H Outside cam No.
range
The synchronous parameter "[Pr.440] Cam No." is set
to other than 0 to 256.
[Operation status at error occurrence]
Synchronous control does not start.
Set a value within the range of 0 to 256.
1C11H Cam not registered Cam data specified in the synchronous parameter
"[Pr.440] Cam No." does not exist on the cam open
area.
[Operation status at error occurrence]
Synchronous control does not start.
Specify the cam No. of an existing cam data.
1C12H Outside cam axis
length per cycle
range
The synchronous parameter "[Pr.439] Cam axis length
per cycle" is set to 0 or lower.
[Operation status at error occurrence]
Synchronous control does not start.
Set a value within the range of 1 to 2147483647.
1C13H Outside output axis
smoothing time
constant range
The synchronous parameter "[Pr.447] Output axis
smoothing time constant" is set to other than 0 to 5000.
[Operation status at error occurrence]
Synchronous control does not start.
Set a value within the range of 0 to 5000.
1C20H Outside setting
method of current
value per cycle after
main shaft gear
range
The synchronous parameter "[Pr.460] Setting method of
current value per cycle after main shaft gear" is set to
other than 0 to 2.
[Operation status at error occurrence]
Synchronous control does not start.
Set a value within the range of 0 to 2.
Error code
(Hexadecimal)
Error name Error details and causes Remedy