3  MAJOR POSITIONING CONTROL
3.2  Setting the Positioning Data
89
3
■Setting positioning data
When using 2-axis circular interpolation control with sub point designation (INC circular sub), set the following positioning 
data.
: Always set, : Set as required, : Setting restricted, : Setting not required
*1 Refer to the following for information on the setting details.
Page 445 Positioning Data
Set a value in "[Da.8] Command speed" so that the speed of each axis does not exceed the "[Pr.8] Speed limit 
value". (The speed limit does not function for the speed calculated by the Simple Motion module during 
interpolation control.)
Setting item Setting required/not required 
for the reference axis
Setting required/not required 
for the interpolation axis
[Da.1] Operation pattern 
[Da.2] Control method 
(Set INC circular sub.)
[Da.3] Acceleration time No. 
[Da.4] Deceleration time No. 
[Da.6] Positioning address/movement amount 
[Da.7] Arc address 
[Da.8] Command speed 
[Da.9] Dwell time/JUMP destination positioning data No. 
[Da.10] M code/Condition data No./Number of LOOP to LEND repetitions/
Number of pitches
[Da.20] Axis to be interpolated No.1 
[Da.21] Axis to be interpolated No.2 
[Da.22] Axis to be interpolated No.3 
[Da.27] M code ON signal output timing 
[Da.28] ABS direction in degrees 
[Da.29] Interpolation speed designation method