10 - 6 Symbol LS3408 Product Reference Guide
Convert Newer Code Types
The scanner supports a variety of code types that are customarily not decodable by attached decoder systems. To
allow compatibility in these environments, the scanner converts these code types to more commonly decodable
symbologies, as per the following chart. Symbologies not listed on this chart are transmitted normally.
When decoding these code types with this parameter disabled, the scanner issues Convert Error beeps and
transmits no data.
*Convert Newer Code Types
Reject Newer Code Types
Module Width
The standard module width is 20 µs.
In the case of an extremely slow decoder system, this module width can be extended to 50 µs through use of this
parameter.
*20 µs Module Width
50 µs Module Width
Scan this code type: Transmitted as:
Code 11 Code 39
GS1 DataBar (14, Limited, and Expanded) Code 128