6. COMMUNICATIONS MEMORY MAP
6-26
GROUP ADDR
(hex)
DESCRIPTION MIN. MAX. STEP
VALUE
UNITS FORMAT
CODE
FACTORY
DEFAULT
GENERAL 0470 Number of Motor Starts 0 50000 1 - F1 0
COUNTERS 0471 Number of Emergency Restarts 0 50000 1 - F1 0
0472 Number of Starter Operations 0 50000 1 - F1 0
0473 Digital Counter 0 1000000000 1 - F9 0
0475 Reserved
... ...
049F Reserved
TIMERS 04A0 Motor Running Hours 1 100000 1 hr F9 0
04A2 Time Between Starts Timer 0 500 1 min F1 0
04A3 Start Timer 1 0 60 1 min F1 0
04A4 Start Timer 2 0 60 1 min F1 0
04A5 Start Timer 3 0 60 1 min F1 0
04A6 Start Timer 4 0 60 1 min F1 0
04A7 Start Timer 5 0 60 1 min F1 0
04A8 Reserved
... ...
04BF Reserved
SR469 04C0 Order Code 0 65535 1 N/A FC136 N/A
MODEL 04C1 Relay Serial Number 3050001 N/A 1 - F9 N/A
INFO. 04C3 Reserved
... ...
04DF Reserved
CALIBRATIO
N
04E0 Original Calibration Date N/A N/A N/A N/A F18 N/A
INFO. 04E2 Last Calibration Date N/A N/A N/A N/A F19 N/A
04E4 Reserved
... ...
04FF Reserved
PHASORS 0500 Va Angle 0 359 1 ° F1 N/A
0501 Vb Angle 0 359 1 ° F1 N/A
0502 Vc Angle 0 359 1 ° F1 N/A
0503 Ia Angle 0 359 1 ° F1 N/A
0504 Ib Angle 0 359 1 ° F1 N/A
0505 Ic Angle 0 359 1 ° F1 N/A
0506 Reserved
... ...
0FFF Reserved