© Munters AB, 2020 88
11.4.3
B
ATCH
W
EIGHER
A
LARMS
1. Go to Control > Feed > Alarms .
NOTE Only mapped systems appear on this screen.
2. Click an
d define the cross auger, feeder, and silo auger alarm parameters:
o
Cross Auger Alarm: Define:
The period in which the auger alarms are active, 24 hours a day or
specific time frames.
Over Runtime: The augers operate when the hoppers switch transmits
a signal to distribute feed. The augers cease operating when hoppers
are full. If the run time exceeds the user defined run time, the auger
active sensor should generate an alarm.
Auger under-time alarm: Under time alarms occur when the auger
motor has been off for longer than the under-time parameter.
Stop Feeding: If enabled, feeding stops when overtime or undertime
alarms are detected.
o
Feeder Alarm. Define:
The period in which the feeder alarms are active, 24 hours a day or
specific time frames.
Feeder overtime alarm: Feeders begin receiving feed when the last
pan sends a signal. Feed distribution continues until the pans are full. If
the feed distribution is longer than the user-defined time, the feeder
active sensor should generate an alarm.
Feeder under time: Feeder under time defines the time required to
generate an alarm when the feeder is not active.
o
Silo Auger Alarm. Define:
Over Runtime (Min): Trio generates an alarm when the silo auger
provides too much feed to the hoppers.