EasyManuals Logo

Munters Trio Poultry Controller User Manual

Munters Trio Poultry Controller
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
© Munters AB, 2020 96
13
Expected Bird Weight
Trio collects bird weight data. Factors to set up when configuring how Trio measures
weight:
Reference Bird Curve: The reference weight is a value that reflects the birds’
expected target weight.
o
Enabled: Trio provides a weight curve (by growth day). The user can choose
an industry standard template or manually define a curve.
o
Disabled: Trio provides a reference weight that can be edited.
Separate male/female weighing: When enabled:
o
Scales can be defined as male, female, or both.
o
Weight range can be specified for both genders.
o
If the bird curve is enabled, there are separate curves for each gender.
To enable editing the weight range and bird scale definition, define at least one
scale in Devices & Sensors. Two bird scales are required for weighing male and
female bird separately.
13.1
Reference Bird Curve
As an option, Trio provides a default growth curve which increases according to the
average weight. If required, there is an option to use a bird curve. These bird curves do not
change according to the birds’ actual weight. If required, you can edit the growth days and
bird weights.
Curve Enabled
Curve Disabled
13.1.1
C
URVE
E
NABLED
1. To enable a bird curve, go to System > Control Strategy > Scales .

Table of Contents

Other manuals for Munters Trio Poultry Controller

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Munters Trio Poultry Controller and is the answer not in the manual?

Munters Trio Poultry Controller Specifications

General IconGeneral
BrandMunters
ModelTrio Poultry Controller
CategoryController
LanguageEnglish

Related product manuals