3. Define:
o
Day: Set the growth day to determine the desired set points for RH, C02 and
NH3. Range 0-999
o
Humidity: Set the humidity level above which air treatment starts. Range 0%-
100%
o
Co2: Set the Co2 level above which air treatment starts. Range 0 - 5000
ppm
o
NH3: Set the ammonia level above which air treatment starts. Range: 0 - 100
ppm
14.2
Defining the Air Quality Settings
When the air quality (CO2/NH3/Humidity) exceeds the specifications defined in the Air
Quality Screen, Trio can increase the ventilation, the heat or both. (Alternatively, additional
treatment can be disabled).
When central heating is employed, the changes to heating are global. When zone heaters
are employed, changes are specific to each heater.
Define:
o
Air Quality Treatment:
Off
By Ventilation (Treatment by Ventilation only is enabled)
By Heat (Treatment by is Heat only is enabled)
By Outside Temp (both Treat by Ventilation and Heat are enabled)
o
Treatment by Ventilation: