Provide ventilation according to the output set by the heat and
ventilation.
o
Growth day stays at zero.
o
Stop water alarm - even when the alarm function is enabled.
Pre-Heat: Pre heat the facility before moving the birds in to the pre-
heat temperature set-point. This mode is used 24 72 hours before
starting a new flock. If you wish to use this mode, the Wizard option
appears. Refer to the next section.
Cleaning: Between batches the facility is cleaned by soaking.
o
Provide ventilation according to the output set by the heat and
ventilation.
o
Stop growth day progress.
Catching: Catching Mode is used when birds are being removed from
the chicken house. In this mode:
o
Provide ventilation according to the level
o
Heat output should be OFF.
o
Growth day stays at zero.
o
Turn on light if enabled. The user defines the lighting intensity.
If you define the mode as Empty, Pre-Heat, Cleaning, or Catching, define the
parameters in Defining House Modes, page 18.
NOTE For information on Brooding, refer to Brood Area, page 70.
3.2.1.2
New Flock Wizard
Trio provides a simple to use wizard to set up the Growing or Pre-Heat modes. Using the
wizard enables defining negative growth days. When starting a new flock Trio:
o
Erases historical data
o
Sets the growth day to zero
o
Increases the batch number by one
o
Records a “New Batch” event