© Munters AB, 2020 62
8.2.1
C
ONTINUOUS
C
OOLING
•
Define:
o
Growth days at which the settings change. Define up to four days.
o
Status: Enable or disable a cooling device.
o
Start temperature (diff): Sets the temperature differential from the cooling
temperature (Temperature Curve) to activate cooling. The calculated
temperature to start cooling is adjusted according to the growth-days.
NOTE Each cooling device operates according to its own temperature (Temperature
Definition).
o
Stop temperature (diff): Sets the temperature differential from the cooling
temperature (Temperature Curve) to stop cooling device.
Stop cooling device temperature = Cooling Target ± Stop temperature
o
Enable from ventilation Level: Select the level (ventilation output) to enable
cooling operation. (Default 1).
NOTE If you want cool pads to operate only in Tunnel mode, 1) enable Tunnel Mode 2) set
up the Temperature Curve so that Tunnel Targe Temperature is below the Cooling
Temperature.
o
Humidity Limit: Stop cooling when the humidity level reaches the level
defined in the Humidity settings.