5.2.3
T
UNNEL
V
ENTILATION
If enabled, once the temperature reaches the Tunnel Set Point, Trio turns on the
tunnel fans and opens the tunnel doors. As in Basic Ventilation, you define the fans to
be used in each level. However, there is no curve between levels.
Even if Extra Ventilation is enabled, Trio will go straight to tunnel mode if the
temperature is above the Tunnel Set Point (skipping over Extra Ventilation).
You can set a differential for each level to ensure that ventilation increases only
when required.
In this example, tunnel fans are at level T6.
Refer to Tunnel Ventilation, page 52 for more details.
Refer to Defining the Wind Chill Factor, page 57 for details on factoring in the
wind chill factor in tunnel mode.