© Munters AB, 2020 66
To define the central on/off heaters:
1. Go to System > Control Strategy > Climate .
2. Define the Heating Method as Central.
3. Go to Climate > Heating.
4. Define:
o
Heater On Temp: Define the difference from the Heat target temperature at
which the heaters turn on. Range: 0.2 - 5⁰ C.
o
Heat Tuning: This parameter determines how aggressively the TRIO
responds to differences between the measured temperature and the target
temperature.
NOTE Munters recommends leaving this parameter at Normal.
Options:
•
Analogue Heaters
•
Heat Cycles
9.2.1
A
NALOGUE
H
EATERS
Define analog ports as heaters in Error! Reference source not found., page Error!
Bookmark not defined..
Define the analogue heaters using the same procedure as the on/off heaters. In addition:
1. Go to Climate > Heating > Settings.