© Munters AB, 2020 65
9
Heating Functions
•
Heating Functions
•
Central Heaters
•
Zone Heaters
9.1
Heating Functions
TRIO supports up to six (6) on/off heating devices and variable heaters. To control the heat,
TRIO has two different programs, one to maintain the target temperature in the entire
house and one program that controls separate heating zones. In the case of the latter, each
heater has a dedicated sensor and unique target temperature.
Trio supports on/off and 0-10V analog heaters. In additions, heaters can run in cycles.
•
Central Heaters
•
Zone Heaters
9.2
Central Heaters
When using central heat, the heater output is defined by the average measured
temperature of all temperature sensors.
As temperature drops, TRIO reduces the amount of ventilation until it provides the
minimum defined amount. If the temperature goes below the target temperature, TRIO
continues to run at minimum ventilation. At the same time, heating begins when the
temperature drops to a user defined temperature.
Define relays output ports as heaters in Error! Reference source not found., page
Error! Bookmark not defined..
In Configuring the Temperature Curve, page 22 define the Heat parameter.
Configuring On-Off heaters requires mapping one fan, inlet, outlet, or tunnel door.