In this example Fan 1 operates according to the levels determined by the temperature
and day, beginning at Level 1. The fan will supply up to 10% of the possible
ventilation. At Level 4, Fan 2 also begins to operate, supplying up to 40% of the
possible ventilation.
Each level shows the maximum possible ventilation capacity. In this example, each fan
has a capacity of 5000 M3/h. At Level 1 this means that the maximum is 50000 M3/h
and at Level 4 10,000 M3/h.
7.2.2
F
AN
O
PTIONS
•
Minimum Ventilation Cycle: Fans run in an on/off cycle with user-defined times.
•
Analog Fans: Fan speed changes as ventilation requirements change.
•
Efficiency fan: Fan runs at a maximum speed percentage defined by the user.
•
Fan Rotation: Different fans running in Minimum Ventilation Cycle can be
designated to run in rotation.